CLGZP - 853931 IRON ALUMINUM ALLOY POWDER

  • MSDS: CLGZP
  • Manufacturer: BASF CORP
  • Product Name: 853931 IRON ALUMINUM ALLOY POWDER
  • National Stock Number: -
Product Identification

Product ID:853931 IRON ALUMINUM ALLOY POWDER
MSDS Date:04/14/1989
FSC:NIIN:Submitter:D DG
Status Code:A
MSDS Number: CLGZP

Responsible Party
BASF CORPORATION
100 CHERRY HILL ROAD, BLDG 119-2
PARSIPPANY, NJ 07054
US

Emergency Phone: 201-316-3000

Info Phone: 201-316-3000 OR 800-424-3900

Preparer: NOT PROVIDED

Cage: 0PK40

Contractor
BASF CORPORATION
PARSIPPANY, NJ 07054 US

Telephone: 201-316-3000 OR 800-424-3900

Cage: 0PK40

Ingredients

FE (IRON)

CAS: 7439-89-6

RTECS: NO4565500


AL (ALUMINUM)

CAS: 7429-90-5

RTECS: BD0330000

OSHA PEL 15 MG/M3

ACGIH TLV: 10 MG/M3

Hazards

LD50 LC50 Mixture:NOT PROVIDED
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EFFECTS OF OVEREXPOSURE: CONTACT WITH
THE EYES AND SKIN MAY RESULT IN MECHANICAL IRRITATION. CHRONIC
OVEREXPOSURE TO IRON OXIDE FUME OR DUST HAS BEEN ASSOCIATED WITH
X-RAY CHANGES OF THE LUNGS; HOWEVE R, IT DOES NOT RESULT IN
ILLNESS. CHANGES ARE DUE TO A BENIGN LUNG CONDITION CALLED
SIDEROSIS, OR IRON PIGMENTATION. ALUMINUM OXIDE HAS NOT BEEN
IMPLICATED AS A CAUSE OF LUNG DISEASE IN HUMAN.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:CONTACT WITH THE EYES AND SKIN MAY RESULT IN
MECHANICAL IRRITATION.
Medical Cond Aggravated by Exposure:NOT PROVIDED

First Aid

First Aid:EYES; IMMEDIATELY WASH EYES WITH RUNNING WATER FOR 15
MINUTES. SKIN: WASH AFFECTED AREAS WITH SOAP AND WATER. REMOVE AND
LAUNDER CONTAMINATED CLOTHING BEFORE REUSE. IF IRRITATION DEVELOPS,
CONSULT A P HYSICIAN. INGESTION: IF SWALLOWED, DILUTE WITH WATER
AND IMMEDIATELY INDUCE VOMITING. NEVER GIVE FLUIDS OR INDUCE
VOMITING IF THE VICTIM IS UNCONSCIOUS OR HAVING CONVULSIONS. GET
IMMEDIATE MEDICAL ATT ENTION. INHALATION: MOVE TO FRESH AIR AID IN
BREATHING IF NECESSARY AND GET IMMEDIATE MEDICAL ATTENTION

Fire Fighting

Autoignition Temp:=480.C, 896.F
Extinguishing Media:USE WATER FOG, DRY POWDER (CLASS D ) AND DRY
CHEMICAL EXTINGUISHING MEDIA.
Fire Fighting Procedures:FIREFIGHTERS SHOULD BE EQUIPPED WITH
SELF-CONTAINED BREATHING APPARATUS AND TURN OUT GEAR.
Unusual Fire/Explosion Hazard:NOT KNOWN

Accidental Release

Spill Release Procedures:SPILLS SHOULD BE CONTAINED AND PLACED IN
SUITABLE CONTAINERS FOR DISPOSAL. THIS MATERIAL IS NOT REGULATED
UNDER RCRA OR CERCLA (SUPERFUND).
Neutralizing Agent:NOT RELEVANT

Handling

Handling and Storage Precautions:NOT PROVIDED
Other Precautions:NOT PROVIDED

Exposure Controls

Respiratory Protection:IF DUSTS ARE GENERATED, WEAR A NIOSH/MSHA
APPROVED DIST MASK.
Ventilation:USE LOCAL EXHAUST TO CONTROL DUSTS.
Protective Gloves:GLOVES AS NECESSARY TO MINIMIZE SKIN CONTACT.
Eye Protection:CHEMICAL GOGGLES.
Other Protective Equipment:PROTECTIVE CLOTHING AS NECESSARY TO MINIMIZE
SKIN CONTACT
Work Hygienic Practices:NOT PROVIDED
Supplemental Safety and Health
ABBREVIATION: N/A = NOT APPLICABLE. N/AV = NOT AVAILABLE. N/K =
UNKNOWN. N/P = NOT PROVIDED. N/R = NOT RELEVANT. N/D = NOT
DETERMINED. N/E = NOT ESTABLISHED. CNS = CENTRAL NERVOUS SYSTEM. GI
= GASTROI NTESTINAL. SCBA = SELF CONTAINED BREATHING APPARATUS.

Chemical Properties

HCC:N1
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:=700.C, 1292.F
Melt/Freeze Pt:M.P/F.P Text:NOT PROVIDED
Decomp Temp:Decomp Text:NOT PROVIDED
Spec Gravity:6.5 G/CM3
Solubility in Water:INSOLUBLE
Appearance and Odor:GREY POWDER ODOR: ODORLESS
Corrosion Rate:NONE

Stability

Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:NONE

Disposal

Waste Disposal Methods:INCINERATE OR BURY IN A LICENSED FACILITY. DO
NOT DISCHARGE INTO WATERWAYS OR SEWER SYSTEMS WITHOUT PROPER
AUTHORITY. CONTAINER DISPOSAL: DISPOSE OF IN LICENSED FACILITY.
RECOMMEND CRUSHING OR OTHER M EANS TO PREVENT UNAUTHORIZED REUSE.

Toxicology

Toxicological Information:ANIMAL STUDES INDICATE THAT CHRONIC
OVEREXPOSURE TO IRON OXIDE DUST DOES NOT CAUSE LUNG IMPAIRMENT OR
FIBROSIS. GAMM-ALUMINA A FORM OF ALUMINUM OXIDE WAS FIROGENIC WHEN
INJECTED INTO THE LUNGS OF ANIM ALS; HOWEVER, ALUMINUM OXIDE HAS
NOT BEEN IMPLICATED AS A CAUSE OF LUNG DISEASE IN HUMANS.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ecology

Ecological:NOT PROVIDED

Transport

Transport Information:D.O.T. PROPER SHIPPING NAME: NONE. DOT HAZARD
CLASS: NONE. DOT SUBSIDIARY RISK: NONE. DOT ID NUMBER: NONE. DOT
LABEL: NONE.

Regulatory

SARA Title III Information:SEC. 313: LISTED.
Federal Regulatory Information:ALL COMPONENTS ARE LISTED ON THE TSCA
INVENTORY.
State Regulatory Information:NOT PROVIDED